  mitsubishi hvdi modules RM400DG-90F high power switching use hvdi (high voltage diode) modules insulated type hvdi (high voltage diode) modules hvm-2024 1 of 5 RM400DG-90F n/a i f ????????? 400 a v rrm ???????? 4500 v 2-element in a pack high insulated type soft recovery diode alsic baseplate application traction drives, high reliability conv erters / inverters, dc choppers outline drawing & circuit diagram dimensions in mm prepared by approved by h.uemura h.yamaguchi 21-sep.-2010 revision: 1.0
mitsubishi hvdi modules RM400DG-90F high power switching use hvdi (high voltage diode) modules insulated type hvdi (high voltage diode) modules hvm-2024 2 of 5 maximum ratings symbol item conditions ratings unit t j = ? 40?+125c 4500 v rrm repetitive peak reverse voltage t j = ? 50c 4400 v t j = ? 40?+125c 4500 v rsm non-repetitive peak reverse voltage t j = ? 50c 4400 v i f dc, t c = 25c 400 a i frm collector current pulse (note 1) 800 a i fsm surge (non-repetitive) forward current t j = 125c, v r = 0 v, t = 10 ms 3.4 ka i 2 t surge forward current integral t j = 125c, v r = 0 v, t = 10 ms 58 ka 2 s v iso isolation voltage rms, sinusoidal, f = 60hz, t = 1 min. 10200 v v e partial discharge extinction voltage rms, sinusoidal, f = 60hz, q pd 10 pc 5100 v t j junction temperature ? 50 ~ +150 c t jop operating temperature ? 50 ~ +125 c t stg storage temperature ? 55 ~ +150 c electrical characteristics limits symbol item conditions min typ max unit t j = 25c ? ? 1.0 i rrm repetitive reverse current v rm = v rrm t j = 125c ? 1.0 ? ma t j = 25c ? 2.55 ? v fm forward voltage i f = 400 a (note 2) t j = 125c ? 2.85 3.45 v t j = 25c ? 0.70 ? t rr reverse recovery time t j = 125c ? 0.90 ? s t j = 25c ? 400 ? i rr reverse recovery current t j = 125c ? 440 ? a t j = 25c ? 370 ? q rr reverse recovery charge t j = 125c ? 580 ? c t j = 25c ? 0.48 ? e rec(10%) reverse recovery energy (note 3) t j = 125c ? 0.75 ? j/p t j = 25c ? 0.55 ? e rec reverse recovery energy (note 4) v cc = 2800 v i c = 400 a v ge = 15 v l s = 150 nh ? d if /d t = 1350 a/s @ t j = 25c 1250 a/s @ t j = 125c inductive load t j = 125c ? 0.85 ? j/p
mitsubishi hvdi modules RM400DG-90F high power switching use hvdi (high voltage diode) modules insulated type hvdi (high voltage diode) modules hvm-2024 3 of 5 thermal characteristics limits symbol item conditions min typ max unit r th(j-c)d thermal resistance junction to case, 1/2 module ? ? 58.5 k/kw r th(c-s) contact thermal resistance case to fin, grease = 1w/mk d (c-s) = 100 m, 1/2 module ? 48.0 ? k/kw mechanical characteristics limits symbol item conditions min typ max unit m t m8: main terminals screw 7.0 ? 22.0 nm m s mounting torque m6: mounting screw 3.0 ? 6.0 nm m mass ? 1.0 ? kg cti comparative tracking index 600 ? ? ? d a clearance 26.0 ? ? mm d s creepage distance 56.0 ? ? mm l p ak parasitic stray inductance 1/2 module ? 44.0 ? nh r aa?+kk? internal lead resistance t c = 25c, 1/2 module ? 0.27 ? m ? note 1. pulse width and repetition rate should be such that junction temperature (t j ) does not exceed t opmax rating (125c). note 2. pulse width and repetition rate should be such as to cause negligible temperature rise. note 3. e rec(10%) is the integral of 0.1v r x 0.1i f x dt . note 4. the integration range of e rec according to iec 60747.
mitsubishi hvdi modules RM400DG-90F high power switching use hvdi (high voltage diode) modules insulated type hvdi (high voltage diode) modules hvm-2024 4 of 5 performance curves forward characteristics (typical) 0 100 200 300 400 500 600 700 800 012345 forward voltage [v] forward current [a] t j = 125c t j = 25c reverse recovery characteristics (typical) 0.0 0.5 1.0 1.5 2.0 0 400 800 1200 1600 2000 current slope [a/s] reverse recovery energies [j/pulse] v cc = 2800v, l s = 150nh t j = 125c, inductive load reverse recovery characteristics (typical) 0.0 0.5 1.0 1.5 2.0 0 100 200 300 400 500 600 700 800 forward current [a] reverse recovery energies [j/pulse] v cc = 2800v, l s = 150nh t j = 125 c , inductive load
mitsubishi hvdi modules RM400DG-90F high power switching use hvdi (high voltage diode) modules insulated type hvdi (high voltage diode) modules hvm-2024 5 of 5 performance curves reverse recovery characteristics (typical) 0.1 1 10 100 1000 forward current [a] reverse recovery time [s] 10 100 1000 reverse recovery current [a] trr irr v cc = 2800v, l s = 150nh t j = 125c, inductive load transient thermal impedance characteristics 0.0 0.2 0.4 0.6 0.8 1.0 1.2 0.001 0.01 0.1 1 10 tim e [s ] normalized transient thermal impedance r th(j-c)r = 58.5k/kw reverse recovery safe operating area (typical) 0 200 400 600 800 1000 0 1000 2000 3000 4000 5000 reverse voltage [v] reverse recovery current [a] v cc 3200v, di/dt < 2ka/ s t j = 125c, l s = 150nh ? ? ? ? ? ? ? ? ? ? = ? ? ? ? ? ? ? ? ? ? = ? exp 1 r z i t n 1 i i ) c j ( th ) t ( 1234 r i [k/kw] : 0.0059 0.0978 0.6571 0.2392 i [sec] : 0.0002 0.0074 0.0732 0.4488


▲Up To Search▲   

 
Price & Availability of RM400DG-90F

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X